GENERAL INFORMATION
EX80-Series insertion electromagnetic flowmeters are designed for use with conductive liquids in 1 to 12” pipe. A choice of materials (stainless steel, brass, and PVC) allows the meter to adapt to a range of temperature, pressure, and corrosive environments.The EX80 insertion seametrics magmeter is highly suitable for difficult applications with changing viscosities and pulsating flows, such as air-driven diaphragm pumps. With no moving par ts, seametrics magnetic flow meters can be used in “dir ty” applications where debris would foul a mechanical meter. Like all magmeters, when used in chemical injection applications, these meters should be installed upstream of the chemical line (or far enough downstream to allow complete mixing of fluids before the meter).Designed for modularity and versatility, the EX80-Series seametrics measurement has a current-sinking pulse output that can be combined with the appropriate transmitter or indicator for the application
Insertion Magmeters Specifications
Materials:
Insertion Magmeters Specifications
- Accuracy: 1% of full scale
- Output: Square wave pulse, opto isolated, 500 Hz @ 20 ft/sec
- Bi-Directional: Direction output, opto isolated
- Empty Pipe Detection: Flow defaults to zero
- Flow Range: 0.2 - 20 ft/sec (.06 - 6.09 m/sec)
- Maximum Pipe Pressure: 200 PSI (13.8 bar)
- Maximum Temperature:
- PVC 130º F (55º C)
- Stainless Steel 200º F (93º C)
- Minimum Conductivity: 20 microsiemens/cm
- Power: 12 - 24 Vdc, 250 mA minimum
Materials:
- Mechanical: 316 SS/PVC
- Electrodes: Hastelloy
- Electrode plate: PVDF
- Housing Cast: powder-coated aluminum
- O-rings: EPDM
- Size: 4" square; 6-7" total length
FEATURES
• No moving par ts
• Economical
• Durable
• Easy to install
• Easy to maintain
APPLICATIONS
• Conductive fluids
• Small pipe applications (1”-12”)
• Industrial processes
• Chemical metering pumps
• Fer tigation
For analog output and display of rate and total, an FT420 can be used. Blind analog output is provided by the AO55. The PD10 can be used to divide the pulse for pacing chemical metering pumps and the DL76 (data logger) is also compatible. Modules can be wall- or meter- mounted. If the EX80 meter is used with a programmable controller, the output signal can be fed direct, with no other conditioning required.EX80-Series fixed depth inser tion meters require special fittings. Factory installation in the fitting ensures correct depth placement in the pipe. The EX80-Series meter can be ordered in a full power model when a source of electricity is available, or in a low power model that can run on an external battery with solar panel. Reverse flow output and immersibility are optional.
Insertion Magmeters Options
Fittings for EX81 Insertion Magmeter Series Meters :
• Economical
• Durable
• Easy to install
• Easy to maintain
APPLICATIONS
• Conductive fluids
• Small pipe applications (1”-12”)
• Industrial processes
• Chemical metering pumps
• Fer tigation
For analog output and display of rate and total, an FT420 can be used. Blind analog output is provided by the AO55. The PD10 can be used to divide the pulse for pacing chemical metering pumps and the DL76 (data logger) is also compatible. Modules can be wall- or meter- mounted. If the EX80 meter is used with a programmable controller, the output signal can be fed direct, with no other conditioning required.EX80-Series fixed depth inser tion meters require special fittings. Factory installation in the fitting ensures correct depth placement in the pipe. The EX80-Series meter can be ordered in a full power model when a source of electricity is available, or in a low power model that can run on an external battery with solar panel. Reverse flow output and immersibility are optional.
Insertion Magmeters Options
- EX81P Fixed Depth Insertion Magmeter
- PVC Insertion Magmeter, for 1" to 3" size.
- EX81S Fixed Depth Insertion Magmeter
- Stainless Steel, for 1" to 3" size.
- EX82P Fixed Depth Insertion Magmeter
- PVC Insertion Magmeter, for 4" to 10" size.
- EX82S Fixed Depth Insertion Magmeter
- Stainless Steel, for 4" to 10" size.
- EX83S Fixed Depth Insertion Magmeter
- Stainless Steel, for 12" size.
Fittings for EX81 Insertion Magmeter Series Meters :
- EF81T-P-100 PVC Tee Fitting, 1" Diameter Male stub end.
- EF81T-P-150 PVC Tee Fitting, 1 1/2" Diameter Male stub end.
- EF81T-P-200 PVC Tee Fitting, 2" DiameterMale stub end.
- EF82S-P-300-16 PVC Saddle Fitting, 3" Diameter
- Installed on 16" long pipe stub. PVC saddle is supplied with Buna-N O-rings only. For chemical service, the O-ring must be removed and the saddle glued on to the pipe with PVC cement.
- EF81T-S-100 304 Stainless Steel Tee Fitting, 1" Diameter
- EF81T-S-150 304 Stainless Steel Tee Fitting, 1 1/2" Diameter
- EF81T-S-200 304 Stainless Steel Tee Fitting, 2" Diameter
- EF82S-B-300 Bronze Saddle Fitting, 3" Diameter
- Fittings for EX82 Insertion Electromagnetic Flowmeter Series Meters:
- EF82S-P-400 PVC Saddle Fitting, 4" Diameter
- EF82S-P-600 PVC Saddle Fitting, 6" Diameter
- EF82S-P-800 PVC Saddle Fitting, 8" Diameter
- PVC saddles are supplied with Buna-N O-rings only. For chemical service, the O-ring must be removed and the saddle glued on to the pipe with PVC cement.
- EF82S-B-400 Bronze Saddle Fitting, 4" Diameter
- EF82S-F-600 Ductile Iron Saddle Fitting, 6" Diameter
- EF82S-F-800 Ductile Iron Saddle Fitting, 8" Diameter
- EF82S-F-1000 Ductile Iron Saddle Fitting, 10" Diameter
- EF82S-F-1200 Ductile Iron Saddle Fitting, 12" Diameter
- EF82W-S-400 316 Stainless Steel Weld Fitting, 4" Diameter
- EF82W-S-600 316 Stainless Steel Weld Fitting, 6" Diameter
- EF82W-S-800 316 Stainless Steel Weld Fitting, 8" Diameter
- EF82W-S-1000 316 Stainless Steel Weld Fitting, 10" Diameter
- EF82W-S-1200 316 Stainless Steel Weld Fitting, 12" Diameter
- Meter mounted displays/converters include 18 feet of cable.
- FT420M/FT420W Pulse & 4-20mA Output Display
- Requires 12-24VDC power. Specify meter or wall mounted.
- AO55M/AO55W Blind 4-20ma Converter
- Requires 24-36VDC power. Specify meter or wall mounted.