Feature
Technical Parameter
Size and Weight
- Ultrasonic water meter Stratified fluid piping design for two-channel measurement, measurement accuracy Range than the width, and less than 0.01m / s starting flow
- Display large amount of information, with the screen display 9 digital display four cumulative flow and instantaneous flow figures
- Design of energy-saving, power-saving features such as automatic meter will empty tube or long-term fluid standstill
- Full IP68 protection class design, the components completely sealed to protect, even if the water can be long-term work
- Design at the time, there were a total of records and data collection functions on the month, day
- Ultrasonic flow meter With multiple communication interface mode; TTL level pulse output and USART interface for easy connection to other low power devices; standard RS485 interface; infrared communication interface; support CJ-188 communication protocol.
- Supports standard MODBUS, M-BUS, HART communication protocol, compatible communications protocol Haifeng ASCⅡ code
- Output signal and diverse: Available two isolated pulse signal output, (which pulse and pulse width equivalent programmable); may also 4-20mA two-wire output
- With online software upgrades
- With Dual PT1000 temperature measurement function, can achieve heat measurement
- Built-quantitative control can be achieved manually or set the time automatically start controller, thus achieving automatic timing quantitative or quantitative irrigation water
- Depending on customer needs to select a variety of units, including cubic US gallons, cubic feet and liters
- Built-in lithium battery, the battery life of more than 6 years
Technical Parameter
Project
|
Parameters
|
Accuracy class
|
2 (measurement period: 1 second)
|
Turndown ratio
|
100, initiating a flow rate of less
than 0.006m / s
|
Measurement Range
|
Water, sewage, water (other liquids
to be customized), and full pipeline
|
Measuring medium temperature
|
0.1-30 ℃
|
Work environment
|
Temperature: -10 ~ 45 ℃; humidity ≤100% (RH)
|
Pressure Rating
|
1.6MPa / 2.5MPa optional
|
Upstream of the flow field
sensitivity level
|
U3
|
Downstream flow field sensitivity
level
|
D0
|
Climatic and mechanical
environmental safety rating
|
Grade C
|
Electromagnetic Compatibility Level
|
E2 level
|
Communication Interface
|
RS485 / USART / IR / USART serial
communication bus, etc. Optional
|
The output signal
|
4-20mA analog two-wire output
(two-way isolation OCT or TTL optional, pulse width programmable)
|
Communication protocol
|
Haifeng fully compatible protocol
(individual very distinct command) also supports the standard MODBUS, M-BUS,
CJ-188 communication protocol
|
Heat measurement
|
Access Dual PT1000 achieve heat
measurement
|
Power supply
|
Built-in lithium battery (3.6V) /
External DC5 ~ 40V
|
Protection class
|
IP68
|
Local Display
|
Two-line display includes nine
cumulative amount, four instantaneous flow, as well as prompt and unit status
|
Data Storage
|
Using EEPROM / FLASH to store data,
cumulative flow automatically record 128 months ago, the first 512 days
|
Flow measurement cycle
|
Measuring status: 1 times / sec
(also can be set to 2 to 4 times / sec); verification status: 4 times / sec
|
Power and Power
|
Built-in 3.6V lithium battery can
be used continuously for more than six years, external DC8-36V
|
Flow Range
Nominal diameter
(Mm)
|
Turndown ratio
R
|
Flow rate (m3/ h)
|
||||
Starting flow
|
Minimum flow Q1
|
Transitional flow Q2
|
Common flow Q3
|
Overload flow Q4
|
||
DN15
|
200
|
0.003
|
0.0125
|
0.020
|
2.500
|
3.125
|
DN20
|
200
|
0.0035
|
0.016
|
0.030
|
3.200
|
4.000
|
DN25
|
200
|
0.007
|
0.020
|
0.030
|
4.000
|
5.000
|
DN32
|
200
|
0.010
|
0.032
|
0.0504
|
6.300
|
7.875
|
DN40
|
200
|
0.015
|
0.100
|
0.160
|
20.000
|
25.000
|
DN50
|
100
|
0.030
|
0.400
|
0.640
|
40.000
|
50.000
|
DN65
|
100
|
0.059
|
0.630
|
1.008
|
63.000
|
78.750
|
DN80
|
100
|
0.064
|
1.000
|
1.600
|
100.000
|
125.000
|
DN100
|
100
|
0.094
|
1.600
|
2.560
|
160.000
|
200.000
|
DN125
|
100
|
0.120
|
2.000
|
3.200
|
200.000
|
250.000
|
DN150
|
100
|
0.270
|
2.500
|
4.000
|
250.000
|
312.500
|
DN200
|
100
|
0.315
|
4.000
|
6.400
|
400.000
|
500.000
|
DN250
|
100
|
0.508
|
4.000
|
6.400
|
400.000
|
500.000
|
DN300
|
100
|
0.770
|
6.300
|
10.080
|
630.000
|
787.500
|
Nominal
|
Dimensions
|
Threaded connection
|
Effective thread length
|
Weight
kg
|
Pressure Rating
MPa
|
|||||
L
|
H1
|
H2
|
W1
|
W2
|
A pipe thread
|
Port Thread B
|
||||
DN15
|
110
|
168
|
17.5
|
58
|
90
|
G3/4B
|
G3/4B
|
10
|
2.2
|
2.5
|
DN20
|
130
|
173
|
24
|
58
|
90
|
G1B
|
G1B
|
12.5
|
2.3
|
2.5
|
DN25
|
160
|
175
|
25
|
58
|
90
|
G11/4B
|
G11/4B
|
13
|
2.5
|
2.5
|
DN32
|
180
|
177
|
31
|
58
|
90
|
G11/2G
|
G11/2G
|
14.5
|
2.8
|
2.5
|
DN40
|
200
|
181
|
31
|
58
|
90
|
G2B
|
G2B
|
188
|
3.3
|
2.5
|