HD1200 Open Channel Flow Meter - Flow Meter Indonesia - Flow meter air, flowmeter solar, gas, Ultrasonic, Vortex, Electromagnetic

Breaking

Kamis, 23 Desember 2021

HD1200 Open Channel Flow Meter

 

HD1200 Open Channel Flow Meter

Overview

  • Advanced level sensing algorithm suppresses the noise level and artifacts and enabled stable measurement.
  • One main unit handles two sensors at once. Two different types of sensors can be installed and each may measures different range.
  • Data logging function to micro SD TM.
  • Flow measurement by measuring catchment level is possible.

Specifikasi Honda Electronic HD1200

 
Model No.HD1200
Channel2
Frequency10 to 60 kHz (select by sensor)
Measurement objectliquid / powder
ResolutionMeasurement1 mm
display1 mm
Accuracy±0.25% F.S.
 Data refresh rate2 sec. approx. (depends on sensor)
Power sourceVoltage100 to 240 V AC ±10 %
Power consumption10 VA
DisplayLCD with backlight
OutputAlarm4 points / channel
250VAC, 5 A (relay contact)
4-20mA currentResolution: 1/4000
(Max. load resistance 600Ω)
InterfaceRS-485 (max. distance: 1200 m or less)
RS-232C (max. distance: 10 m or less)
MemorymicroSDTM *1
Operation temperature-20 to 70℃
MaterialABS
ProtectionIP66 equivalent
Dimension (WxDxH mm)176x84x237
Weight1.8 kg

NOTE : Weir type flowmeter is available on CH1

*1 : microSDTM is a trademark of SD Card Association

 
Model No.Sensor
TS40-5 TS40T-5
Frequency40 kHz
Measurement range(1/2 value for powder)0.3 to 20m0.3 to 15m
Directive angle (half of full angle)12°(-6dB)8°(-3dB)22°(-6dB)16°(-3dB)
Operation temperature-20 to 70℃
MaterialEpoxy/silicone/ PPPVDF
ProtectionIP68 equivalentIP68 equivalent
Dimension (mm)dia. 84x90dia. 98x87
Sensor cable length5m
Weight500g860g
Mounting screwR1 (PT1)
G1 (PF1)

  • NOTE : Weir type flowmeter is available on CH1*1 : microSDTM

    is a trademark of SD Card Association

  • ●TS40T-5 is chemical resistant.
    ●The sensors cannot be used in hydrofluoric acid environment.

    * Contact us if sensor cable extension is required.