Dwyer VFC and VFCII Series Visi-Float® Acrylic Flow Meter is a direct reading, precision machined, clear acrylic body flow meter suitable for both gas and liquid applications. This Series consists of two 5" (127 mm) scale flow meters, the VFC and VFC II. The VFC features PVC 1" female NPT connections and the VFC II units are equipped with acetal thermoplastic 1" male NPT fittings.
Dwyer VFC and VFCII Series Visi-Float® Acrylic Flow Meter |
Flow includes Flow Transmitters, Flow Sensors, Flow meters, Sight Flow Indicators and Water Meters. Mass Flow meters, Controllers, Flow Indicators and Controllers are ideal for measurement of flow rates. Flow Switches come as paddle, thermal, piezo, and shuttle/piston. Flow meters indicate flow rate. The different sensors include dial, in-line, ultrasonic, orifice plate, totalizing meters, variable area, venturi, or with switch output. The different designs of the flow meters have a variety of applications.
Dwyer VFC and VFCII Features
- Bodies are cut and precision machined from solid, clear acrylic blocks allowing for complete visual inspection
- White background allows for better visibility of the float increasing reading accuracy
- Direct reading scales are hot stamped into the plastic eliminating the need for troublesome conversions and increasing product operating life
- Precision machined tapered bore enables high repeatability
- Low installation costs with back or end connection options
Application
- Medical equipment
- Laboratory equipment
- Air samplers
- Gas analyzers
- Pollution monitors
- Chemical injectors
- Cabinet purging
- Remediation
- Osmosis skids
Dwyer VFC and VFCII Specification
Service | Compatible gases and liquids. |
Wetted Materials | Body: Acrylic plastic; O-ring: Buna-N (fluoroelastomer available); Metal parts: SS; Float: SS; Fittings: VFC: PVC; VFCII: Acetal thermoplastic. |
Temperature & Pressure Limits | 100 psig (6.9 bar) @ 120°F (48°C); |
Accuracy | 2% of FS. |
Process Connection | VFC: 1" female NPT back connections. End connections optional. VFCII: 1" male NPT back connections. End connections optional. |
Scale Length | 5" typical length. |
Mounting Orientation | Mount in vertical position. |
Weight | 24 to 25 oz (.68 to .71 kg). |
Agency Approvals | Meets the technical requirements of EU Directive 2011/65/EU (RoHS II). |