Omron E8FC IoT Flow Sensor - Flow Meter Indonesia - Flow meter air, flowmeter solar, gas, Ultrasonic, Vortex, Electromagnetic

Breaking

Senin, 17 Januari 2022

Omron E8FC IoT Flow Sensor

Omron E8FC IoT Flow Sensor ‘Onsite IoT’ uses production floor data to help minimize machine downtime and backtracking and increase machine operation stability and productivity. Offering a wide variety of components including sensors and controllers and further expanding the IoT product lineup to collect onsite data, OMRON can totally help you bring IoT innovation to your manufacturing sites.
Omron E8FC IoT Flow Sensor

Omron E8FC IoT Flow Sensor Features

  • Multi-sensing of “Flow rate + temperature” for preventing a sudden stops or manufacturing
  • Various lineup of replacement adapters to enable easy replacement of your current pressure gauges and flow
  • Analog current output function in addition to the IO-Link communications function that can perform self-diagnosis of abnormalities in the sensor


Specifications

ModelPNP (COM2)E8FC-25D
PNP (COM3)E8FC-25T
NPNE8FC-25
Applicable
diameter
Nominal diameter B3/8"1/2"3/4"1"
Nominal diameter A10 A15 A20 A25 A
Applicable fluidThe fluid must not corrode the material of the wetted part (for example, water or a fluid whose conductivity is equivalent to that of water).
Permissible pressure *110 MPa
Flow rate
monitoring
*2
Rated flow rate range0.6 to 14 l/min1 to 30 l/min1.5 to 60 l/min2 to 100 l/min
Inner diameter setting (10 A, 15 A, 20 A, 25 A)
Display range0 to 16 l/min0 to 33 l/min0 to 66 l/min0 to 110 l/min
Zero cutting flow rate *30.6 l/min1 l/min1.5 l/min2 l/min
Display resolution (l/min)0.1/1 (Selectable)
Flow rate monitoring
response time
Control output: 1.0, 2.5, 5, 10, 30, 60 s
Flow rate monitoring
precision
± (7.0% of measured value + 2.0% F.S.) or less
Flow rate repeatability / F.S.
(prescribed for each
response time)
1 s: ±3.5%, 2.5 s: ±2.5%, 5 s: ±1.6%, 10 s: ±1%, 30 s: ±0.8%, 60 s: ±0.6%
Ambient temperature
characteristics *4
±1.0% F.S./10°C
HysteresisVariable
Temperature
monitoring
*5
Temperature monitoring
rated range
0 to 85°C
Temperature monitoring
precision
±2.5°C
Temperature repeatability±0.5°C
Control
output
judgment
(selectable)
Standard modeJudge if the measured value is the threshold value or more (or less).
Window modeJudge if the measured value is within the upper and lower limits.
Display methodNumerical value indication: 4-digit 7-segment white LED with inverting function
Status indicators: The content of indication is selectable from green, orange, red, and OFF.
Output indicator: OUT1 operation (orange), OUT2 operation (orange)
Unit indicator: l/min (White), % (White), °C (White), ST (White)
Communication indicator: Lighting when communications are in progress (green)
Delay setting1 to 9999 ms (Select a function from invalid, ON delay, OFF delay, and one-shot.)
Connection methodM12, 4-pole connector type
Output ch1
(selectable)
Control outputFlow rate control output (N.O./N.C.)
E8FC-25D/-25T: PNP
E8FC-25: NPN
30 VDC or less, Class 2, 100 mA max., residual voltage 1 V or less
Pulse output1/ 10/ 100/1000 l
Output ch2
(selectable)
Control outputFlow rate control output (N.O./N.C.) / temperature control output (N.O./N.C.)
E8FC-25D/-25T: PNP
E8FC-25: NPN
30 VDC or less, Class 2, 100 mA max. residual voltage 1 V or less
Analog current output *7Flow rate analog output /temperature analog output
Current output 4 to 20 mA (maximum load resistance 350Ω or less)
(Display value ± 2% of F.S.)
Pulse output1/ 10/ 100/1000 l
External inputSmart tuning, One-point tuning,
short-circuit current 1.5 mA or less, input time 20 ms or more
IO-LinkIO-Link specificationVer 1.1
Baud rateE8FC-25D: COM2 (38.4kbps)
E8FC-25T: COM3 (230.4Kbps)
Data lengthPD Size: 6 byte
OD Size: 1 byte (M-sequence type: TYPE_2_V)
Minimum cycle timeE8FC-25D (COM2): 3.2 ms
E8FC-25T(COM3): 2.0 ms
Power
supply
Power supply voltage15 to 30 VDC (including 10% ripple (p-p)), Class 2
Power consumption2,880 mW or less
(When power supply voltage is 30 V, current consumption must be 96 mA or less.
When power supply voltage is 15 V, current consumption must be 192 mA or less.)
Protection circuitPower supply reverse connection protection, output short-circuit protection, and output reverse connection protection
Environment
resistance
Ambient temperature
range
-20 to 80°C in operation and storage, respectively (no condensation)
Applicable fluid
temperature
0 to 85°C (no icing on the pipe surface)
Ambient humidity range35 to 85%RH in operation and storage, respectively (no condensation)
Withstand voltage500 VAC 50/60 Hz 1min
Vibration resistance
(destruction)
10 to 2000 Hz, double amplitude 1.5 mm, 2 hours in X/Y/Z direction each
Shock
resistance
(destruction)
500 m/s2, three times in X/Y/Z direction each
Protective structureIP67
Pollution degree3
Altitude2,000 m or less
Installation placeIndoor
MaterialsWetted partDetecting unit: SUS304L, O-ring: FKM
Other than wetted partHead: PPSU, display unit: PES, button: PBT, chassis: SUS304L, nut: SUS304
WeightApprox. 190 g
Accessories• Ferrite core x 1 (TDK's Model ZCAT1 730-0730A)
• User's manual (Japanese, English, and Chinese), one each
• Compliance sheet
• Index list


Download Catalog: Omron E8FC IoT Flow Sensor

Ref: Omron.co.id

Pages