Dinel HLM–35 Hydrostatic level meter - Flow Meter Indonesia - Flow meter air, flowmeter solar, gas, Ultrasonic, Vortex, Electromagnetic

Breaking

Senin, 21 Februari 2022

Dinel HLM–35 Hydrostatic level meter

Dinel HLM–35 Hydrostatic level meter is a compact measuring device containing a ceramic or stainless steel strain gauge sensor and evaluation electronics in a stainless steel probe. The ceramic sensor is resistant to different against various liquids (water, oil, coolants, water solutions, etc.).
Dinel HLM–35 Hydrostatic level meter

The probe is produced in a configuration with a valve or a capillary, which serves to deliver atmospheric pressure to the probe. The front side of the probe is open, which makes the level meter more resistant against the adhesion of coarser soiling. The level meter does not include any elements that can be set. LED signal function.

Dinel HLM–35 Hydrostatic Level Meter Benefit

  • Intended for various liquids (water, oil, coolants, water solutions, etc.)
  • High long-term stability
  • Accuracy 0,5% within the total range
  • Measuring range up to 100 m (H2O)
  • Thread process connection
  • Current or voltage output
  • LED indicators
  • Variant with an option of settings with a magnetic pen within the selected range

Dinel HLM–35 Hydrostatic level meter Specifications

Working environment (EN 60079-10-1) no explosive hazard area
Supply voltageHLM–35_–_ _- _- I- _- _ _ _ _12 ... 34 V DC
 HLM–35_–_ _- _- U- _- _ _ _ _12 ... 34 V DC
Current outputHLM–35_–_ _- _- I- _- _ _ _ _4 ... 20 mA
Voltage outputHLM–35_–_ _- _- U- _- _ _ _ _0 ... 10 V
Consumption (empty voltage output) HLM–35_–_ _- _- U- _- _ _ _ _ max. 8 mA
Permissible overload1.5x of range
Basic accuracy (non-linearity, hysteresis, repeatability) 0.5% of range
Long-term stability0.3 % / year
Temperature error for zero and range between0 ... +50°C max. 0.04% / K
Temperature compensation range0 ... +50°C
Operating temperature range (temperature of the media) -20 ... +70 °C
Max. load resistance for current output (at U = 24 V DC) Rmax= 600 Ω
Min. load resistance for current output Rmin= 1 kΩ
Protection class type HLM–35_–_ _- _- _- C- _ _ _ _IP67
type HLM–35_– _- _- _- (A,B,V,H)- _ _ _ _IP68
Cabletype HLM–35_–_ V- _- I- _- _ _ _ _PVC 2 x 0.75 mm2
type HLM–35_–_ V- _- U- _- _ _ _ _PVC 3 x 0.5 mm2
type HLM–35_–_ K- _- I- _- _ _ _ _PE 2 x 0.25 mm2 with capillary
type HLM–35_–_ K- _- U- _- _ _ _ _PE 3 x 0.25 mm2 with capillary
Weight sensor190 g
cable (1 m)60 g


Download Catalog: Hydrostatic level meter HLM–35