McCROMETER FPI Mag Insertion Electromagnetic Flow Meter |
McCROMETER FPI Mag Accuracy
AMI / AMR Smart Output™
Simple Installation
Lower Costs
Line sizes
Robust construction
Use in hazardous locations
- Class 1, Division 2, Groups A-D, T5
- Class 2, Zone 2, Groups A-D, T5
Certifications
- ISO 9001:2015 certified quality management system
- NSF/ANSI/CAN 61 & NSF/ANSI 372
- Certified by MET to UL 61010-1 and MET C22.2 No. 61010-1-04
- NEC & CEC: Class 1, Division 2, Groups A-D, Groups A-D, T5; Class 2, Zone 2, Groups A-D, T5
McCROMETER FPI Mag Specifications Measurement
Volumetric flow in filled flow conduits 4” (100 mm) to 138” (3,500 mm) utilizing insertable electromagnetic averaging sensor. Flow indication in English Standard or Metric units.
Flow Measurement
- Method : Electromagnetic
- Calibrated accuracy for forward and bidirectional sensors :
±0.5% from 1 f/s to max velocity (on next page), up to ±1% for 0.3 to 1 f/s
±1% for reverse flow - Linearity : 0.3% of Range
- Repeatability : 0.2% of Reading
- Direction measurement :
395 sensor - Forward flow measurement and reverse flow indication
394 sensor - bidirectional flow measurement
Materials
- Coating : Fusion bonded epoxy (NSF 61 approved) coated 316 stainless steel
- Insertion hardware : 316 Stainless Steel
- Compression seal : Silicone Rubber
- Sensor electrodes : 316 Stainless Steel
Temperature Range
- Operation : -10 to 60°C (14 to 140°F) up to 250 PSI
- Storage : -15 to 60°C (5 to 140° F)
Note regarding storage : During freezing conditions and when meter is not in use, sensor
must be removed from pipe and stored in dry conditions.
NOTE: Damage to the sensor caused by allowing the sensor freeze in the pipe is not
covered by the warranty.
Electrical Connections
- Quick Connect
- Compression gland seals
IP Rating
- Standard model :
Quick Connect (IP68)
Compression gland seals (IP68) - HL model :
Quick Connect (IP67)
Compression gland seals (IP67)
Sensor Submersibility Depth
- With standard quick connect 1.8 m (6 ft.)
- With optional strain relief cable 9 m (30 ft.)
Certifications and Approvals
- Standard Model :
ISO 9001:2015 certified quality management system
NSF/ANSI/CAN 61 & NSF/ANSI 372
Certified by MET to UL 61010-1 - HL Model T :
ISO 9001:2015 certified quality management system
NSF/ANSI/CAN 61 & NSF/ANSI 372
Certified by MET to UL 61010-1 and MET C22.2 No. 61010-1-04
Class I, Division 2, Groups A-D, T5
Class I, Zone 2, IIC T5
System Options
- Hastelloy® electrodes
- Additional sensor cable up to 475’ (500’ max for model 395 and 200’ max for model 394)
- Extension to hardware clearance
- Annual verification / calibration
- Sensor insertion tool
- Stainless steel ID tag
Download Datasheet : McCROMETER FPI Mag Electromagnetic Flow Meter