Signet 2551 Magmeter Flow Sensor |
Signet 2551 Magmeter Features
- Test certificate included for -X0, -X1
- Patented Magmeter technology*
- No moving parts
- Bi-directional flow
- Empty pipe detection
- Installs into pipe sizes DN15 to DN900 (0.5 to 36 in.)
- Operating range 0.05 to 10 m/s (0.15 to 33 ft/s)
- Accurate measurement even in dirty liquids
- Polypropylene and PVDF retaining nuts standard, Valox optional
- 4 to 20 mA, digital (S3L), frequency, relay output (Display only)
- No pressure drop
- Corrosion resistant materials; PP or PVDF with SS, Hastelloy-C, or Titanium
- Multi-language display menu available
Applications
- Chemical Processing
- Water and Wastewater Monitoring
- Metal Recovery and Landfi ll Leachate
- Commercial Pools, Spas, and Aquariums
- HVAC
- Irrigation
- Scrubber Control
- Neutralization Systems
- Industrial Water Distribution
Signet 2551 Magmeter Specifications
General | ||
Operating Range | 0.05 to 10 m/s | 0.15 to 33 ft/s |
Pipe Size Range | DN15 to DN900 | ½ to 36 in. |
Linearity | ± 1% reading plus 0.1% of full scale | |
Repeatability | ±0.5% of reading @ 25 °C (77 °F) | |
Minimum Conductivity | μS/cm | |
Wetted Materials | ||
Sensor Body/Electrodes and Grounding Ring | -P0, -P1, -P2: PP/316L SS | |
-T0, -T1, -T2: PVDF/Titanium | ||
-V0, -V1, -V2: PVDF/Hastelloy-C | ||
O-rings | FKM (standard), | |
EPR (EPDM), FFKM (optional) | ||
Case | PBT | |
Display Window | Polyamide (transparent nylon) | |
Protection Rating | NEMA 4X/IP65 | |
Electrical | ||
Power Requirements | 4 to 20 mA | VDC ±10%, regulated, 22.1 mA max. |
Frequency | to 24 VDC ±10%, regulated, 15 mA max. | |
Digital (S3L) | to 6.5 VDC, 15 mA max. | |
Auxiliary (only required for units with relays) | to 24 VDC, 0.4 A max. | |
Reverse Polarity and Short Circuit Protected | ||
Current Output 4 to 20 mA | Loop Accuracy | 32 μA max. error (25 °C @ 24 VDC) |
Isolation | Low voltage < 48 VAC/DC from electrodes and auxiliary power | |
Maximum Cable | 300 m (1000 ft) | |
Error condition | 22.1 mA | |
Max. Loop Resistance | 300 Ω | |
Compatible with PLC, PC or similar equipment | ||
4 to 20 mA load needed | ||
Frequency Output | Output Modes | Freq., or Mirror Relay (display version only) |
Max. Pull-up Voltage | 30 VDC | |
Max. Current Sink | 50 mA, current limited | |
Maximum Cable | 300 m (1000 ft) | |
Compatible with Signet Model 8900, 9900, 9900-1BC, 9950 | ||
Digital (S3L) Output | Serial ASCII, TTL level 9600 bps | |
Compatible with Model Signet 8900, 9900, 9950 and 0486 | ||
Relay Specifications | ||
#1, #2 Type | Mechanical SPDT | |
Rating | 5 A @ 30 VDC max., 5 A @ 250 VDC max. | |
#3 Type | Solid State | |
Rating | 50 mA @ 30 VDC, 50 mA @ 42 VAC | |
Hysteresis | User adjustable for exiting alarm condition | |
Alarm On Trigger Delay | Adjustable (0 to 9999.9 sec.) | |
Relay Modes | Off , Low, High, Window, and Proportional Pulse | |
Relay Source | Flow Rate, Resettable Totalizer | |
Error Condition | Selectable; Fail Open or Closed | |
Display | ||
Characters | 2 x 16 | |
Contrast | User-set in four levels | |
Backlighting (only on relay versions) | Requires external 9-24 VDC, 0.4 mA max. | |
Max. Temperature/Pressure Rating | ||
Storage Temperature | -20 °C to 70 °C | |
Relative Humidity | 0 to 95% (non-condensing) | |
Operating Temperature | Ambient | -10 °C to 70 °C |
Media | 0 °C to 85 °C | |
Maximum Operating Pressure | 10.3 bar @ 25 °C | |
1.4 bar @ 85 °C | ||
Shipping Weight | ||
0.680 kg | 1.50 lb | |
Standards and Approvals | ||
CE, FCC, UL, CUL, NSF (3-2551-PX-XX version only) | ||
RoHS compliant, China RoHS | ||
NEMA 4X / IP65 Enclosure (with cap installed) | ||
Manufactured under ISO 9001 for Quality and ISO 14001 for Environmental Management and OHSAS 18001 for Occupational Health and Safety |
Download Datasheet: Signet 2551 Magmeter Flow Sensor
Reference : gfps.com