Kobold TSK Flap Flow Meter/Switch |
Additional Advantages
- A large spectrum of wetted materials and linings
- Magneto-resistive signal transmission
- Special design for high temperature applications
Applications
- Control of cooling- and flushing processes
- Chemical industry
- Water- and waste-water technology
- Power-plants
- Machinery-building
Kobold TSK Flap Flow Meter Specifications
- Sensor Materials: 1.4404 (316 L) / 1.4571 (316 Ti) (TSK-S) steel / stainless steel (TSK-C from DN125) Hastelloy® C-22 (TSK-H) PTFE / Hastelloy® C-22 (TSK-P) other materials on request
- Process connection: sandwich acc. EN 1092, ASME B16.5, DIN 2512,
special connections on request Nominal pressure: PN 40, ASME Cl150 / 300 (standard) (TSK-S/C/H) PN 16, ASME Cl150 (standard) (TSK-P) higher pressure rates optional - Process temperature:
-40 °C ... +300 °C (TSK-S/C/H)
-20 °C ... +125 °C (TSK-P) - Ambient temperature: -40 °C ... +80 °C
- Accuracy: liquid/gas:
± 2.5% of full scale
± 0.2% with transmitter (ES) - Repeatability: ± 0.5%
- Protection: IP 65 (EN 60529)
Certification
- Explosion protection: BVS 03 ATEX H/B 112
- CE-Marking: Pressure Equipment Directive 97/23/EG
Display
- Materials:
aluminum (stove-enameled)
stainless steel (as option) - Electrical outputs: inductive switch microswitch
others on request - Ambient temperature:
-40 °C ... +80 °C (without switch)
-40 °C ... +65 °C (with switch)
Download Datasheet: Kobold TSK Flap Flowmeter / Switch
Reference : kobold.com